Appsecure logo

CVE-2025-25675: Critical Vulnerability in Tenda AC10 Firmware

A critical command injection vulnerability has been identified in Tenda AC10 V1.0 V15.03.06.23, allowing arbitrary command execution. Organizations must prioritize immediate remediation to mitigate risks.

CRITICALCVSS 9.8 · Published February 20, 2025

Not a customer? See how AppSecure simulates real world attacks to protect your infrastructure.

Speak to Experts

A command injection vulnerability has been identified in Tenda AC10 V1.0 V15.03.06.23. This vulnerability allows attackers to execute arbitrary commands via the formexeCommand function, where the str variable receives the cmdinput parameter from a POST request. The cmd_buf variable is directly utilized in the doSystemCmd function, leading to a critical security risk.

With a CVSS score of 9.8, this vulnerability is classified as critical. The severity is underscored by the potential for high confidentiality, integrity, and availability impacts, making it vital for organizations using affected systems to act swiftly.

Risk to organizations includes unauthorized access to sensitive data and system compromise. Attackers may leverage this vulnerability to execute arbitrary commands, posing a severe threat to the integrity and availability of network resources.

Organizations should prioritize patching immediately to protect against potential exploitation.

Vulnerability Details

The official description of this vulnerability states that Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerability located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, allowing for arbitrary command execution.

This vulnerability falls under the CWE classifications CWE-77 (Command Injection) and CWE-94 (Code Injection).

The CVSS score of 9.8 signifies a critical severity level, indicating an urgent need for remediation.

Affected products include Tenda AC10 firmware version 15.03.06.23, with the vulnerability being published on February 20, 2025.

Technical Analysis

The root cause of this vulnerability is improper handling of user input in the formexeCommand function. The attack vector is network-based, and the attack complexity is low, as no privileges or user interaction are required for exploitation.

The vulnerability requires no privileges to exploit, and user interaction is not necessary. The potential impacts on confidentiality, integrity, and availability are all rated as high.

Risk & Impact Analysis

The real-world deployment of this vulnerability poses significant risks to organizations. The ability for an attacker to execute arbitrary commands can lead to full system compromise, unauthorized data access, and service disruptions.

The blast radius potential is extensive, particularly in environments where the affected firmware is deployed. Organizations using Tenda AC10 devices must assess their exposure and implement appropriate security measures.

Given the critical nature of this vulnerability, organizations should address it in their priority patch cycle.

Exploitation Status

Signal

Status

Known Exploit

No

Public PoC

No

Actively Exploited

No

Ransomware Use

No

Affected Versions

The affected version is Tenda AC10 firmware version 15.03.06.23. All versions prior to the vendor patch are susceptible to this vulnerability.

Mitigation & Remediation

To mitigate this vulnerability, organizations should apply the latest firmware updates from Tenda. Ensure that devices are configured securely, limiting unnecessary access and implementing network controls to restrict exposure.

If unable to patch immediately, consider implementing intrusion detection systems to monitor for unusual activity and potential exploitation attempts. Organizations should validate remediation through continuous penetration testing to identify similar weaknesses.

Detection Guidance

Organizations should monitor logs for indicators of exploitation attempts, such as unusual command execution patterns or unauthorized access attempts. Behavioral anomalies in network traffic should also be assessed.

Network signatures may provide additional insights into potential exploitation of this vulnerability, allowing for timely response actions.

AppSecure Threat Intelligence Insight

The long-term significance of this vulnerability highlights the necessity for ongoing vigilance in securing IoT devices and embedded systems. As command injection vulnerabilities continue to be prevalent, organizations must adopt a proactive approach to security.

This incident illustrates the importance of thorough security assessments and the implementation of secure coding practices. Organizations should prioritize securing their infrastructure and regularly review their security posture.

For more information on securing your infrastructure and understanding vulnerabilities, organizations can explore our vulnerability management program. Additionally, consider reviewing our penetration testing methodology for best practices in assessing security vulnerabilities.

Lastly, organizations should stay informed about new vulnerabilities by following updates from trusted sources and implementing regular training for their security teams.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Latest CVEs. Recently published vulnerabilities from the NVD database.

View all vulnerabilities
CVE IDSeverity
CVE-2025-65418HIGH
CVE-2025-65417MEDIUM
CVE-2025-65416MEDIUM
CVE-2025-65415MEDIUM
CVE-2025-61314HIGH

Protect Your Business with Hacker-Focused Approach.